References

PĄTNÓW Power Plant

Konin

Installed boilers:

Boiler Type Qty Capacity [t/h] /Output Power [MW] Steam Temperature [oC] Steam Pressure [MPa] Fuel Start-up Year
OB 6 650 t/h 540/540 13,5/2,6 lignite 1967 - 1969
BB 1 1345 t/h 540/568 26,7/5,1 lignite 2007
 

Installed FGD plants:

Boiler Thermal or electric output Flue gas quantity [mn3/h] Sulphur content in fuel in % Desulphurisation efficiency in % Absorbent Final product Start-up Year
  4 x 200 MWel 2 x 2 100 000 0,6 max 1,1 97 limestone powder 50% gypsum pulp 2008
BB-1345 460 MWel 1 950 000 0,6 max 1,1 95 limestone powder gypsum 2008

2008 - Gypsum dehydration and storage installation and liquid waste treatment system from FGD Plant


BACK TO THE MAP OF IMPLEMENTATIONS