Fluidised bed boilers enable the reduction of nitric and sulphur oxides emission during the combustion process itself. It means that they don't require the construction of separate and costly flue gas desulphurisation plants. RAFAKO has designed and delivered seven circulating fluidised bed boilers fired with hard coal. We have also submitted a significant number of offers for lignite fired, circulating fluidised bed boilers.
The construction of this boiler type is based on a licence acquired from EVT (currently Alstom Power). Apart from circulating fluidised bed boilers, RAFAKO has delivered 10 lignite fired, bubbling bed boilers (5 with 125 t/h capacity and other 5 OF-140 type) for Komorany Heat & Power Plant in Czech Republic.

To send your query to our consultants, fill in the contact form below.!
more
AFK-c5
| Boiler type: |
Forced flow |
| Firing method: |
Fluidizet bed |
| Max. continuous rating: |
5 MW |
| Water temperature inlet/outlet: |
80/150°C |
| Water pressure inlet: |
1,63 MPa |
| Gross efficiency: |
91% |
| Fuel type: |
Bituminous coal |
| Net calorific value: |
15 MJ/kg |
| Additional informations: |
CFB water test boiler |
| Installations: |
Dębieńsko Coal Mine (1) |
OFz-450B
| Boiler type: |
Natural circulation |
| Firing method: |
Circulating fluidized bed |
| Max. continuous rating: |
125 kg/s |
| Live steam temperature outlet: |
510°C |
| Live steam pressure outlet: |
10 MPa |
| Feedwater temperature: |
205°C |
| Gross efficiency: |
92,2% |
| Fuel type: |
Bituminous coal |
| Net calorific value: |
18-24 MJ/kg |
| Additional informations: |
CFB steam boiler |
| Installations: |
Żerań CHP Plant (1) |
OFz-450A
| Boiler type: |
Natural circulation |
| Firing method: |
Circulating fluidized bed |
| Max. continuous rating: |
125 kg/s |
| Live steam temperature outlet: |
510°C |
| Live steam pressure outlet: |
10 MPa |
| Feedwater temperature: |
205°C |
| Gross efficiency: |
92,2% |
| Fuel type: |
Bituminous coal |
| Net calorific value: |
22-28 MJ/kg |
| Additional informations: |
CFB steam boiler |
| Installations: |
Żerań CHP Plant (1) |
OFz-425
| Boiler type: |
Natural circulation |
| Firing method: |
Circulating fluidized bed |
| Max. continuous rating: |
118 kg/s |
| Live steam temperature outlet: |
560°C |
| Live steam pressure outlet: |
16,1 MPa |
| Reheat steam temperature outlet: |
560°C |
| Reheat steam pressure outlet: |
3,5 MPa |
| Feedwater temperature: |
250°C |
| Gross efficiency: |
91,5% |
| Fuel type: |
Bituminous coal |
| Net calorific value: |
15-16,7 MJ/kg |
| Additional informations: |
CFB steam boiler |
| Installations: |
Power Plant Siersza (2) |
OFz-230
| Boiler type: |
Natural circulation |
| Firing method: |
Circulating fluidized bed |
| Max. continuous rating: |
64 kg/s |
| Live steam temperature outlet: |
540°C |
| Live steam pressure outlet: |
13,8 MPa |
| Feedwater temperature: |
158/205°C |
| Gross efficiency: |
91,5% |
| Fuel type: |
Bituminous coal |
| Net calorific value: |
17-20,1 MJ/kg |
| Additional informations: |
CFB steam boiler |
| Installations: |
Bielsko-Biała II CHP Plant (1) |
OFz-75
| Boiler type: |
Natural circulation |
| Firing method: |
Circulating fluidized bed |
| Max. continuous rating: |
20,8 kg/s |
| Live steam temperature outlet: |
455°C |
| Live steam pressure outlet: |
4,5 MPa |
| Feedwater temperature: |
105°C |
| Gross efficiency: |
91,5% |
| Fuel type: |
Bituminous coal |
| Net calorific value: |
17-20,1 MJ/kg |
| Additional informations: |
CFB steam boiler |
| Installations: |
POLPHARMA Pharmaceutical Plant