rafako logo
polish version
  • Advanced search
  • Site map
  • RSS
    • Mission
      Activity
      Management Board
      Company basic documents
      Quality, Environment, Safety
      Photo gallery
      Interesting links
    • Production of boiler components
      Boilers
      Enviroment protection plants
      Service
      References
      Heat exchangers
      Liquidation of stocks
      Order the publication
      Survey
    • Current events
      Press releases
      Company in media
      Contact for media
    • Justyna Kowalczyk
    • Events calendar
      Current reports
      Periodic reports
      Basic financial data
      Stock-exchange listing
      Authorities
      Shareholders
      Shareholders General Meetings
      Share information
      Corporate governance
      Stock analysts
      Contact data for investors
    • Jobs offers
      Application form
      konkurs
    • Contacts
      Contact form
      Road access
  • Products
  • Production of boiler components
  • Boilers
    • Hard coal
      • Stoker fired boilers
      • Pulverised fuel hot water boilers
      • Pulverised fuel fired boilers with steam drum
      • Pulverised fuel fired, once through, steam boilers
      • Fluidised bed boilers
    • Lignite
    • Oil, gas, fuels combination
    • Waste derived fuel
    • Exhaust gas down - stream gas turbine
    • Boiler views
  • Enviroment protection plants
  • Service
  • References
  • Heat exchangers
  • Liquidation of stocks
  • Order the publication
  • Survey
  • Home Page
  • Products
  • Boilers
  • Hard coal
  • Pulverised fuel fired, once through, steam boilers

Pulverised fuel fired, once through, steam boilers

The achievement of high steam generation efficiency values required the complete modification of boiler steam - water system, when compared with drum system. Due to the licence acquired from Sulzer, RAFAKO became a leading manufacturer of such boilers, even though the number of lignite fired boilers was significantly smaller than the number of hard coal fired ones. Opole Power Plant with its four BP-1150 boilers is our major reference within this field.

To send your query to our consultants, fill in the contact form below.!

more
  • BP-1150
  • BP-1025

BP-1150

Boiler type: Once-through
Firing method: Tangential
Max. continuous rating: 320 kg/s
Live steam temperature outlet: 540°C
Live steam pressure outlet: 18,3 MPa
Reheat steam temperature inlet/outlet: 335/540°C
Reheat steam pressure inlet: 4,2 MPa
Feedwater temperature: 255°C
Gross efficiency: 91,7%
Fuel type: Bituminous coal
Net calorific value: 23 MJ/kg
Additional informations: Steam boiler
Installations: Opole Power Plant (4)

Zoom
Zoom
Zoom
Zoom

BP-1025

Boiler type: Once-through
Firing method: Tangential
Max. continuous rating: 285 kg/s
Live steam temperature outlet: 540°C
Live steam pressure outlet: 178 MPa
Reheat steam temperature inlet/outlet: 330/540°C
Reheat steam pressure inlet: 36,3 MPa
Feedwater temperature: 275°C
Fuel type: Bituminous coal
Additional informations: Steam boiler
Installations: Power Plant Taiyuan, Chiny (2)

Zoom
  • Print  |  Add to bookmarks
  • © RAFAKO S.A. | ul. Łąkowa 33 47-400 Racibórz | tel. +48 032 410 10 00 | info@rafako.com.pl
  • Legal notice | Privacy Policy | Created by ENIGMATIS POLSKA